amana ptac code a2

Next, try a hard reset. Refrigeration errors indicate there is a fault with your PTACs refrigeration or cooling system. If the internal overload control is in the on position, your PTAC unit wont heat the room properly. SUGGESTED ACTION:Attempt to rebind Wireless Thermostat or Replace Wireless Thermostat. Status:Load Shedding Engaged. The Amana furnace first broke down and stopped cycling Feb 2014. While holding the arrows, press the COOL button twice. C2 means the device is recirculating the air present inside the room. Some taxis charge extra ( . When we took the front cover off, the filter was dirty. These documents may help you identify parts when youre troubleshooting. Large delta between thermostat and return. The technician will investigate for underlying issues with your wiring. My PTAC unit will not blow heated air . The fan run but no heat. On the other hand, you may also have too much pressure on either side. Your email address will not be published. Page 15: Digital Control Operation This is a PBE123G35CB. Any of these codes are a signal that your devices indoor coils are starting to freeze. Remember, sometimes an error code can prevent your PTAC from running correctly, so you should try and fix it with urgency. Next, turn off the power to the PTAC and remove the cover. A dusty filter may prevent the system from reading the indoor temperature correctly. Quarteira is expecting a sell-out summer season for 2023, as visitors seek holidays to safe and established destinations within Europe. STATUS:Wireless Remote Thermostat failure. NOTE: All PTAC 7000, 9000, 12000 units come with a standard 3.5 kW power cord. The best way to fix a C2 error code is by checking the seal around the unit. However, the wireless thermostat is no longer working. Easy to Unsubscribe, 2023 ALL RIGHTS RESERVED | POWERED BYPTAC UNITS, The Complete Guide to Amana PTAC Error Codes. Many Thanks for clear and concise instructions. 2. STATUS:Brown Out Protection engaged. SUGGESTED ACTION: Check for blower motor, compressor, or electric heat operation. Using the error code as a pointer, you can determine if a manual reset will get your PTAC unit working smoothly. The error code LS usually pops up when the compressor and the electric heat go off position. Power was lost or voltage is low, Suggested Action:Clean Filter or Remove Air Blockage, Status:Outdoor Coil Thermistor temperature high, Suggested Action:Clean Condenser Coils, Check Fan for fault. When this happens, the device will be unable to cool the space adequately. How do i fix this? atwood helium refrigerator troubleshooting. Amana packaged terminal air conditioner units are known for their reliability, but as with any product, things can go wrong. You dont need to reset your Amana PTAC device. When the red light appears next to the off button, the system has been successfully reset. The code H1 typically indicates that the input voltage is too high. This category of error codes means a particular component has completely stopped working. Most likely, the thermistor is above or below the standard operating tolerance. The other cause, however, could be a broken fan. Consider moving the PTAC to an area with surrounding temperatures above 430F. One of the largest producers of PTACs (Packaged Terminal Air Conditioners) is Amana, known for producing some of the most reliable PTAC units around. (Meaning Wrong Service Board Configuration). As a solution, it will need to be replaced. Applying a manual reset to this situation wont get your Amana PTAC device working smoothly. The HVAC.com team surveyed 100 Charlotte-area homeowners to learn about their heating and cooling ne. The plug is not connected. Let us know what model your Amana is so that we can double check this. Unit will not condition space with door open. Replace both the indoor thermistor and thermostat. Carefully lift off the front plastic cover by lifting up and pulling toward you. FP means your Amana PTAC unit is now working in Freeze Protection. 2. Check if anything is blocking the outdoor unit and remove it. There is a source of conducting heat in the room (burner, lamp, etc. STATUS: Indoor Freezing Lockout (ICT IAT > 20) +10 Min. The Amana air conditioner essentially comes in three types, PTAC's . SUGGESTED ACTION:Replace Red Indoor Coil Thermistor . Contact Us No movement. Its your home air system. If you need to replace parts, your warranty may cover them. The HP error code is an indication that the Amana PTAC is in danger of overheating. Amana control boards can be ordered here. Next select the model number from Model drop down box. Status:Front Desk switch is closed. 2020-11-24 Symptom Possible Causes; Motor rocks slightly when starting: This is normal start-up for variable speed motor. Suggested Action:Clean Filter or Remove Air Blockage or Close Vent Door or Improve indoor to outdoor seal. Also, you want to make sure the refrigerant level isnt low. You will also want to check for any blown fuses. RESULT: Outdoor Coil temperature too high for outdoor ambient temperature. Turn off the master switch and wait at least five seconds. In the event that unit does not operate, check the ), Honeywell Air Conditioner Troubleshooting (9 Issues Fixed), 4 Ways to Enter the Whirlpool Duet Washer Diagnostic Mode, 8 Reasons Why the Fridge Is Not Cold But The Freezer Is, Frigidaire Microwave Keeps Blowing Fuse (8 Fixes Shared! If the thermostat portion of your unit isnt working properly, youll need to call an HVAC technician. Compressor is switched off. I have a Friedrich Quietmaster (22V) unit, about 10 years old. In such a case, the PTAC cannot cool the space properly. Then plugged back in. In this case, you will need to check the voltage coming to the unit and adjust to the proper levels. Gl will cause the code, because a fan signal must be present before heater is allowed to energize. S e r v i c e M a n u a l R 4 1 0 A M o d e l s, Packaged terminal air conditioners & heat pumps (36 pages), Packaged terminal air conditioners & heat pumps (28 pages), Ptac - r410a models packaged terminal air conditioners (55 pages), Ptacs ductless split systems vertical ptacs (29 pages), Ptac pd series (electronic controls) packaged terminal air conditioners packaged terminal heat pumps (28 pages), Packaged terminal air conditioners (17 pages), Digital packaged terminal air conditioners (13 pages), Ptac pd series (electronic controls) packaged terminal air conditioners packaged terminal heat pumps (11 pages), Packaged terminal air conditioners packaged terminal heat pumps wallmaster p series (40 pages), Floor console / under ceiling dual type (20 pages), Manual will be automatically added to "My Manuals", Remote Wall Thermostat / Low Voltage Wire Connections, Electronic Control Error Code Diagnostics, Optional Hand Held Remote Control Operation, Refrigeration System Sequence of Operation, Single Phase Running & Locked Rotor Amperage, Wiring Diagrams for Cool with Electric Heat, Wiring Diagrams for Heat Pump with Electric Heat, Air Conditioner Friedrich PTAC Service Manual, Air Conditioner Friedrich 920-087-09 (12/10) Installation And Operation Manual, Air Conditioner Friedrich PTAC Installation & Operation Manual, Air Conditioner Friedrich PTAC Series Installation & Operation Manual, Air Conditioner Friedrich PTAC series Parts Manual, Air Conditioner Friedrich PTAC ZONEAIRE PREMIER Service & Parts Manual, Air Conditioner Friedrich PTAC - R410A Service Manual, Air Conditioner Friedrich MR09C1H Brochure & Specs, Air Conditioner Friedrich PDE07K Service Manual, Air Conditioner Friedrich PDH07K3SF Product Profile, Air Conditioner Friedrich PDE07K Product Profile, Air Conditioner Friedrich PDE07K Series Parts Manual, Air Conditioner Friedrich PTAC Brochure & Specs, Air Conditioner Friedrich PTAC ZONEAIRE SELECT Service & Parts Manual, Air Conditioner Friedrich WallMaster PE07K Service Manual, Air Conditioner Friedrich P/N9359944072-01 Operating Manual, Page 12: Remote Wall Thermostat / Low Voltage Wire Connections, Page 16: Digital Control User Input Configuration, Page 17: Optional Hand Held Remote Control Operation, Page 18: Electronic Control Error Code Diagnostics, Page 21: Refrigeration System Sequence Of Operation, Page 22: Sealed Refrigeration System Repairs, Page 25: Capillary Tube Systems/Check Valve, Page 26: Reversing Valve Description/Operation, Page 30: Single Phase Running & Locked Rotor Amperage, Page 35: Wiring Diagrams For Cool With Electric Heat, Page 36: Wiring Diagrams For Heat Pump With Electric Heat, Page 37: Remote Thermostat Wiring Diagram. If they are dirty, clean them with HVAC coil cleaner. The code F6 indicates a failure in the yellow Indoor Discharge Thermistor. While the solutions for these errors may be simple, they may also require a technician to repair certain defective parts. Your email address will not be published. As a guide for the price if you take a taxi from the rank outside the airport its about 40 each-way (80 return), or by pre-booked private transfer about 25-30 each-way (60 return) so it's well worth booking in advance if possible. However, the solutions available for these issues may surprise you. The error codes C1, C3/and C4 pop up when the indoor coils begin freezing. Note that higher voltages are capable of delivering extreme shock, and you should exercise great caution when checking voltage for your unit. Call an HVAC electrician if these tips dont help you turn your PTAC back on. Repairing the compressor isnt a DIY project. CODE: C1. Following the above reset instructions worked to bring my Amana on line. This typically indicates an issue with the compressor, and you will need to repair/replace any broken parts within that system. All outputs are switched off, Suggested Action:Open front desk switch to allow occupant unit operation, Status:Un-Configured Service Board All operation held awaiting configuration. Turn the master switch to the off position. The error code ON shows up when the PTAC works tandemly with the wired thermostat, not wireless. We can group these codes into four categories: System modes point to errors in the operating framework of your Amana PTAC unit. d2 air conditioner / heat pump is wired as part of a circulatory system and the outdoor unit requires more airflow than the indoor units airflow capacity. To fix this, you would need to ask the front desk to re-open the switch so that the unit can resume regular operation. Unit will not condition space with door or window open, Suggested Action:No action required. The code L6 indicates that the air flowing out of the unit (known as discharge or head) is too hot for normal operation. (Meaning Malfunctioning Red Indoor Thermistor). For home owners, this manual is usually used to troubleshoot any issues and DIY light repair. When moving the air conditioner, always call an authorized Trane service representative for disconnection and re-installation. Your unit may also display codes for issues related to various airflow systems and temperatures. The error code L7 shows up when your outdoor unit fails to receive adequate power. Check the state of the compressor, blower motor, and other electrical components. Suggested Action:Close Room Door. friedrich air conditioner error code a2senorita bread recipe. Consider having an expert check and replace the thermistor. It sounds like the main board on the unit might have also gone out. If the setting reads C3, change this to C. Note that this applies to PTAC units that also have. If the unit does detect an error, active failure, mode, or lockout, the display will show one of the following codes. The code means the discharged air is sweltering. Press down on both buttons simultaneously. Dirty condenser coils could also trigger the error code LC. To exit Freeze Protection, move the unit to an area where the temperature is over 43. These usually require very general maintenance on parts such as coils and filters. In this case, you will need to replace the battery inside the device. If the fan is working properly, you can fix this problem by cleaning the condenser coils. Did the test and the heater doesnt cut on. The Friedrich PTAC features a 24V AC terminal for connection to an auxiliary fan that may be used to transfer air to adjoining rooms. The room temperature measured by the wireless remote thermostat or indoor ambient thermistor active sensor falls below 40F. SEER is a way to rate the energy efficiency of air conditioners. To fix this, follow the same troubleshooting steps for the Indoor Coil Freeze Warning. Decide whether a high-efficiency AC is worth your while (and your $$). If thats too much trouble, you can also, What Size Air Conditioner Do You Need? This also typically means that the compressor is off and the EHH switch is closed. You may also need to contact an electrician. CODE: C3. Follow Us. The code LC will display when the red Outdoor Coil Thermistor is reaching temperatures that are too hot for normal operation. Amana TTW Heat Pump 11K 230/208V (PBH113G35CB) Founded in 1934 Amana as a company has been manufacturing air conditioners for a long time. Auxiliary fans can provide conditioning to multiple rooms without the Auxiliary Fan Ready requirement of multiple PTAC units. In a hurry? In other words, all outputs for the unit are off. For units that operate using heat pumps instead, change the setting to H instead. Can you tell me what may be wrong? From the blog trane ptac a2 error codes. System modes can often be fixed by changing the settings directly or improving the units surroundings. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); For years, Total Home Supply has been a trusted distributor of indoor and outdoor home products. If set to low, the condenser motor shuts off but the compressor continues to run. Code will reset after cleaning. Essentially, thats because you can identify different Amana PTAC troubleshooting codes by putting the units in diagnostic mode. The error code F6 comes on when the yellow indoor thermistor wont work. The code F4 means that the red Indoor Coil Thermistor is no longer working or has exceeded its operating tolerance. A red light should appear, signaling a successful reset. The code Fb indicates that the battery in the PTAC remote is too low. The code "C2" means that the air inside the room is being recirculated through the unit. STATUS:Window Switch Lockout (LS & INN open). You should call Amana tech support at 877-376-0214. The only solution is to replace it. No error code will present. If you have a multimeter, check the power cord and the outlet youre using to ensure theyre working. The unit runs off of a wall thermostat. 50+ Years of PTAC Knowledge We did a diagnostics test (held up/down & off [possibly cool, i cant remember right now its hot lol] ) & its stopped working. Unit will not condition space with door or window open. After this, make sure the capillary tube is not restricted in any way. Youll need to call in an air conditioning repair expert to fix it. It is an Amana 15000 BTU PTAC Model number is PTH153G50AXXAA. (Meaning Faulty Exit Temperature Sensor). Depending on the fault, a simple manual reset may help get your unit working properly again. Depending on whats wrong with an Amana PTAC unit, the fastest way to solve the problem is to reset the system. STATUS: Emergency Hydronic Engaged. Typically this can be fixed by cleaning the air filter. It often occurs due to a lack of servicing. Facebook Twitter Instagram Linkedin Twitter Instagram Linkedin, Gree has many types of air conditioner units like Split Air Conditioner, Window Air conditioners, Tower Air Conditioners, Cassette Air conditioners, Package Air , 2022-04-03 Join Date Sep 2011 Location Las Vegas Posts 33 Post Likes Likes (Given) 0 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received) 0, Colorful Beet Salad on Arugula With Sherry Vinaigrette, Roasted Green Pepper, Onion and Red Potatoe Salad, Greek Tuna Salad Pita Sandwiches With Feta Cheese. Amana PTAC manual including information on how to perform proper installation and service instructions on PTAC (Packaged Terminal Air Conditioners) units can be found below. There may also be a green light (also known as the status light) in the lower-left corner of the touchpad below the OFF button. Therefore, the system may not work smoothly even if you reset the Amana PTAC unit. Still need help? STATUS:Control is configured to respond to a wired thermostat. 22, 24, and 26 cu. Replace board and display. This setting will disengage when the room temperature rises above 43F. Your email address will not be published. PTAC-GA E 12 AB D Series Designation PTAC (Packaged Terminal Air , craving ice cold water during pregnancy; natural oils with ceramides; catherine brown rich little; mountain view springers nh; virgo weekly horoscope michele knight, Projects worth spreading. When the compressor stops working, and the EHH switch goes off position, the error code EH will show up. To move the unit out of this mode, you will need to contact the front desk to change the status from Un-Rented to Rented. Note that this does not apply to all units. Required fields are marked *. While holding both buttons, double-tap the Cool button on your PTAC unit. With cooling issues, you may also hear a loud noise coming from the unit. The unit cools properly if the fan speed on the control board is set to high. As Quarteira and the central Algarve are expecting a sell-out 2023, we strongly advise you to get your flights and accommodation as soon as possible, before prices increase and sell out. 2020-10-28 Problem Possible Cause; The airconditioner doesn't work: There is a power failure, Wait for the power return. Indoor Ambient Thermistor (IAT) without a wireless remote thermostat reads outside the range -20F to 200F. This ensures that airflow is conditioned entirely through the unit. But now im not getting anything to work.no lights come on display panel. Fix Check the air filter and clean it if it's dirty. If your Amana PTAC isnt cooling, check the thermostat. The code Eo indicates that the service board on the unit is not configured properly. (Meaning Failed Yellow Indoor Thermostat). I bought a new cord and installed it . b. (Basically unplugging the unit, waiting 5 minutes, and repowering) Ask Your Own HVAC Question Have until plugged for a while. Second, it means that the wireless thermostat is no longer sending signals to the unit control. SUGGESTED ACTION:Check for Blocked Outdoor Air or Clean Coil. All PTAC 15000 units come with a standard 5 kW power cord For units using our optional heating cords (2.5 kW, 3.5 kW, and 5 kW) please refer to page 14 for the proper accessory part numbers and. Amana Air Conditioner Error Codes - All Done Ac Maintenance Indoor Ambient Thermistor reads outside the range -20F to 200F & the wireless thermostat is not communicating to the unit control or Indoor Ambient Thermistor (IAT) without a wireless remote thermostat reads outside the range -20F to 200F. If you encounter any of the following error codes while troubleshooting your PTAC unit, youre dealing with airflow issues. Thanks to clever innovation, you can troubleshoot your Amana PTAC unit without any tools or technical skills. Check your air filter. As with any piece of HVAC technology, Packaged Terminal Air Conditioners (PTACs) will likely encounter maintenance issues. If thats too much trouble, you can also get a new or refurbished unit with a great warranty. To fix this, you would either need to rebind the thermostat or replace it entirely. This keeps the essential elements from freezing and causing damage. SUGGESTED ACTION:Clean Filter or Remove Air Blockage or Close Vent Door or Improve indoor to outdoor seal. The code On appears in the display when the unit has been configured to work with a wired thermostat (instead of a wireless one). This creates a problem with both conditioning and freshness. The likely triggers are a dirty filter, broken fan, or faulty blower. The code F5 means that the wireless thermostat itself has failed. Gl will cause the code, because a fan signal must be present before heater is allowed to energize. Select the brand from the drop down menu. Motor won't start: 1. Leds slightly lit on heat and off. My amana unit will display whether youre using heat or cool but you cannot adjust temperature and you cannot turn on fan speed or constant fan. Unit will not condition space with door open. Once you have the code, check it on the above Amana AC troubleshooting guide to see what it means and possibly fix it. Clean the vent screen (the screen on top of the unit) with a soft cloth or vacuum hose. Suggested Action:Open front emergency hydronic switch to allow occupant unit operation. From foqfgx.amis-ste-therese.fr See details MALFUNCTION OR PROTECTION: EEPROM MALFUNCTION If the PCB is to. The LS switch is closed. While holding the buttons, turn the master switch back on. A window is opened 2. These can, in turn, affect the operation of the compressor. This allows the unit to check for errors and produce a code that describes its current operating state. Other faults to consider include: Check that the Amana PTAC unit connects appropriately to a power source. If the compressor is overloaded, your units heating function will stop working. A red light beside the off button means you have successfully reset your Amana PTAC unit. Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Check the air filter and clean it if its dirty. Amana Diagnostic Codes; Your email address will not be published. Wall Air Conditioners Ultimate Buyers Guide, How To Choose The Right Hotel Air Conditioner. The LS switch is aso closed. SUGGESTED ACTION:No action if a wired thermostat is being used. The manual reset process with clear any settings that you have changed and return everything back to the factory default. Amana - Reconditioned 12,000 BTU PTAC Unit - Better Class - Digital Controls - Heat Pump - 20a - 208/230v. An Amana furnace and air conditioner were purchased in Dec 2013 after my 21 year old furnace died. (BTUs), The Exhaustive Guide to Heating and Cooling Your Tiny Home. All rights reserved. The end goal is to diagnose the fault and possibly fix it. 7 E7 Linesync timing failure. Once all menus have been satisfied push the SUBMIT button. In this case, it will need to be replaced. Status:Open Door Lockout (DS1 & DS2 open; wireless). PTAC From the beginning, every Amana brand product has been made with the same core philosophy: to provide our customers with high-quality products that are reliable, meet their needs, and last longer than the rest. Exit the LS mode by switching on the LS switch. $609.47. For example, there may be a problem if the display is blank or the touchscreen isnt responding. Your email address will not be published. A red dot will flash in the corner of the display. The indoor thermistor (red) is no longer working correctly. Place the front plastic cover back onto the unit and enjoy. . The LS switch is closed. If your device shows any of the error codes below, you may need to call in a refrigerator repair expert. 11 Affordable Ways to Keep Your Home or Apartment Warm in the Winter, How to Troubleshoot & Reset Your Amana PTAC Unit. The Freeze Protection kicks in when the temperature of the environment is below 40. To fix this, you will need to change the configuration mode to the proper setting in the configuration menu. Check the owners manual for your unit if you cant find it on your own. While these modes are not necessarily maintenance issues, they can be the cause of your unit not functioning as expected. Locate the down and up arrow buttons on the unit. The unit will move out of Freeze protection mode once the thermostat or thermistor read above 43 . When overheating, the overload switch will then open to stop the compressor until it cools down. You may also need to replace it entirely. WOULD THINK THERE WOULD BE A RESET BUTTON. My Amanda Digital in wall unit how do i reset it because we had lost power to the building everything came back on except that. Goodman does not assume any responsibility for property damage or personal injury. First, the Indoor Ambient Thermistor (black) is reading outside of the predetermined range (-20 to 200 ). If none of the Amana PTAC troubleshooting suggestions above resolve the issue, its likely to do with your refrigerant. To see other quality Amana brand Heating and Air Conditioning products, view our website at www.amana-hac.com or call your local sales representative at 800-647-2982 for complete details. Still get A 2 code. 7 E7 Linesync timing failure. SUGGESTED ACTION: Open load shedding switch to allow occupant unit operation. 10. Clean the air filter if dirty, and replace a broken fan or faulty blower. In this guide, well walk you through the list of diagnostic codes that your Amana PTAC may display and provide some possible solutions. Motor rocks, but won't start. The code F2 indicates that the Wireless Remote Thermostat has failed. Check for bad wiring and breakage in the connection. An error code H1 means the incoming voltage is too high. Heres a step-by-step to resetting your PTAC unit manually: Thanks to the self-diagnostic feature, its easy to troubleshoot and diagnose a faulty Amana PTAC device. In order for your PTAC to display an error code, you will first need to put the machine in diagnostic mode. Press and hold the UP (+) and DOWN (-) arrow buttons. We have helped countless customers shop for high-quality items -- from air conditioners, to heating units, to water heaters, and more -- and have set up this blog as an extension of our commitment to helping homeowners become informed of the things that matter to them. Unit runs fine if run as it is but if i connect it to the thermostat i get a br error and unit wont run. The codes oP or nP may appear if the unit detects that a door or window is open in the room. The code Eo indicates that the service board on the unit is not configured properly. Lets find out. In such a case, the PTAC cannot cool the space properly. Replace board and display. Push and hold both the heat and cool buttons. The thermostat is working optimally, but the indoor thermistor (black) is working outside the normal range. This error code is a sign of a more significant issue with the condenser fans. This means that the compressor and the electric heat are both off. The error code On indicates the unit works in tandem with a wired thermostat instead of a wireless system. If there are kinks, straighten them with a coil fin comb. To fix this, you will want to start by cleaning the filter and checking for defects in the fans or blowers. TRANE PTAC ERROR CODE A2 RECIPES. Set it to your desired temperature, and ensure the settings are on "cool," and "auto." If the thermostat portion of your unit isn't working properly, you'll need to call an HVAC technician. ), 4 Whirlpool Duet Washer ResetTechniques (Explained! Recent Friedrich Heating and Cooling questions, problems & answers. At HVAC.com, our writers create solutions that put you in control of your HVAC system. LS means Load Shedding. Book a local HVAC expert for PTAC repairs. What do i do? Simply close the open window or door. SUGGESTED ACTION:Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube. I cant get any heat . SUGGESTED ACTION:Enter Configuration Menu and set C3 to C for coolers with electric heat or H for heat pumps. Here are the things to check: Unplugged unit - If the power cable is unplugged, the PTAC won't get any power. You should still check the voltage for this error to detect any possible blown fuses or bad power cords. This setting will disengage when the room temperature rises above 43F. To reset the search for a new search click the SEARCH button. Your unit may also diagnose issues related to the refrigeration system and cooling temperatures. 4. Youll have to remove the front cover to access it in most cases. Where there are normally numbers to indicate temperature, there will either be a set of dashes ( ) or a diagnostic code. last minute costume ideas female; what happened to hunter brown. Turn off the master power switch under the control panel. Compressor and Electric heat is switched off. The system will stop working to prevent energy wastage. Amana PTC153G50AXXX 15000 BTU Class PTAC Air Conditioner - 30 Amp Follow these simple steps to manually reset your Amana PTAC unit: Make sure the unit is plugged in. In this situation, the device goes into Heat Sentinel mode to prevent damage to essential parts. Cooling issues may also be a direct result of low refrigerant levels. The best way to fix a "C2" error code is by checking the seal around the unit. SUGGESTED ACTION: Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube. Otherwise, see Configuration Settings. While holding those buttons, turn the master switch back on. The code FP indicates the system is in Freeze Protection mode. Consider having an expert check and help you service your PTAC. ), Unit operating in tandem with wired (instead of wireless) thermostat, Compressor and electric heat in the off position, Non-working compressor and closed EH switch, Clean the filter and remove any obstruction, Double failure (indoor black thermistor and thermostat), The indoor thermistor and thermostat are not working, Working black indoor thermistor but faulty thermostat, Working thermostat but failing black indoor thermistor, Locate the up/+ and Down/ arrow switches on your PTAC, While holding down these buttons, press cool twice to enter diagnostic, If theres no error code, the display will show a pair of dashes (), But if theres an error, a fault code will pop up on display, which you should note somewhere, Ensure your PTAC is plugged in (into the power outlet), Lift off (by pulling towards you) the front cover to access the master switch, Switch off the master switch for at least 5 seconds, Hold down the cool and heat controls and while holding them, switch on the master switch, Wait for a red display near the OFF button to show a successful reset, Put back the front cover and restart your PTAC.

Sava Senior Care Leadership Team, Lifecore Fitness Parts, Articles A